Hoşgeldiniz
Hızlı ve Güvenli Alışverişe Giriş Yapın!
Üye Değil misiniz?
Kolayca Üye Olabilirsiniz.

Sigma-Aldrich M34152 Mitochondrial Membrane Potential Kit sufficient for 100 fluorometric tests (flow cytometry) 1 KIT

Sigma-Aldrich M34152 Mitochondrial Membrane Potential Kit1 KIT
Synonym(s): JC-10
Assay NACRES: NA.25
SDS için Resmi Tıklayınız... 
Sigma-Aldrich M34152 Mitochondrial Membrane Potential Kit sufficient for 100 fluorometric tests (flow cytometry) 1 KIT          
PROPERTIES
usage sufficient for 100 fluorometric tests (flow cytometry) 
detection method fluorometric 
storage temp. −20°C
 
DESCRIPTION 
General description
Mitochondria generate a potential across their membranes due to the activities of enzymes of the electron transport chain. During apoptosis, collapse of the mitochondrial membrane potential (MMP) coincides with the opening of the mitochondrial permeability transition pores, leading to the release of cytochrome c into the cytosol, which in turn triggers other downstream events in the apoptotic cascade.
Application
Mitochondrial Membrane Potential Kit has been used to detect mitochondrial membrane potential (MMP)[1] of PC-12 cells.[2]
Suitability
This kit is suitable for the flow cytometric detection of Mitochondrial Membrane Potential in mammalian cells and for screening apoptosis inhibitors and activators.
Principle
This kit utilizes JC-10, a superior alternative to JC-1, for determining the loss of the MMP in cells. Although JC-1 is widely used in many labs, its poor water solubility often results in precipitation in aqueous buffers when used at higher concentrations. At higher concentrations, JC-10 exhibits greater aqueous solubility than JC-1. Similar to JC-1, JC-10 is a cationic, lipophilic dye that is concentrated and forms reversible red-fluorescent JC-10 aggregates (λex = 540/λem = 590 nm) in the mitochondria of cells with a polarized mitochondrial membrane. In apoptotic cells, MMP collapse results in the failure to retain JC-10 in the mitochondria and a return of the dye to its monomeric, green fluorescent form (λex = 490/λem = 525 nm). This kit can be used for monitoring apoptosis and for screening apoptosis inhibitors and activators.
Bu ürünün fiyat bilgisi, resim, ürün açıklamalarında ve diğer konularda yetersiz gördüğünüz noktaları öneri formunu kullanarak tarafımıza iletebilirsiniz.
Görüş ve önerileriniz için teşekkür ederiz.
Sigma-Aldrich M34152 Mitochondrial Membrane Potential Kit sufficient for 100 fluorometric tests (flow cytometry) 1 KIT Sigma-Aldrich M34152 Mitochondrial Membrane Potential Kit sufficient for 100 fluorometric tests (flow cytometry) 1 KIT LB.SA.MAK160-1KT
Sigma-Aldrich M34152 Mitochondrial Membrane Potential Kit sufficient for 100 fluorometric tests (flow cytometry) 1 KIT

Tavsiye Et

*
*
*
 
DLAB ürünlerinde özel fısatlar
IdeaSoft® | E-Ticaret paketleri ile hazırlanmıştır.