Hoşgeldiniz
Hızlı ve Güvenli Alışverişe Giriş Yapın!
Üye Değil misiniz?
Kolayca Üye Olabilirsiniz.

Merck 100602 Chlorine Test (total chlorine) Method: photometric, DPD 0.010 - 6.00 mg/l Cl₂ Spectroquant® 1200 tests / Fibre case

Marka
Stok Kodu
LB.M.1006020002
13.082,83 TL + KDV
15.699,40 TL
Stok Sorunuz
Merck 100602 Chlorine Test (total chlorine)  1200 tests / Fibre case
Catalogue Number 100602
Overview This Spectroquant® Chlorine test allows the accurate quantification. Chlorinated disinfectants are still in common use all over the world, their major applications being in the chlorination of drinking water and swimming pools. In weakly acidic solution free chlorine reacts with dipropyl-p-phenylenediamine (DPD) to form a red-violet dye that is determined photometrically. In the presence of potassium iodide, also combined chlorine is measured in this reaction.

The method is analogous to EPA 330.5, APHA 4500-Cl2 G, and DIN EN ISO 7393-2.
This method is USEPA approved for drinking water.

All our Cell and Reagent Test Kits are equipped with the unique Live ID which allows seamless method recognition and contains essential information such as lot number, expiry date, and automatic calibration updates.
Merck 100602 Chlorine Test (total chlorine) Method: photometric, DPD 0.010 - 6.00 mg/l Cl₂ Spectroquant® 200 tests / Fibre case 
Product Information
HS Code 3822 19 00
Quality Level MQ100
Safety Information according to GHS
Hazard Pictogram(s) Hazard Pictogram(s)
Hazard Pictogram(s)
Hazard Statement(s) H319: Causes serious eye irritation.
H360FD: May damage fertility. May damage the unborn child.
H373: May cause damage to organs through prolonged or repeated exposure if swallowed.
Precautionary Statement(s) P202: Do not handle until all safety precautions have been read and understood.
P260: Do not breathe dust/ fume/ gas/ mist/ vapours/ spray.
P264: Wash skin thoroughly after handling.
P280: Wear protective gloves/ protective clothing/ eye protection/ face protection/ hearing protection.
P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P308 + P313: IF exposed or concerned: Get medical advice/ attention.
Signal Word Danger
Storage class 6.1D Non-combustible, acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects
WGK WGK 2 obviously hazardous to water
Storage and Shipping Information
Storage Store at +15 °C to +25 °C.
Bu ürünün fiyat bilgisi, resim, ürün açıklamalarında ve diğer konularda yetersiz gördüğünüz noktaları öneri formunu kullanarak tarafımıza iletebilirsiniz.
Görüş ve önerileriniz için teşekkür ederiz.
Merck 100602 Chlorine Test (total chlorine) Method: photometric, DPD 0.010 - 6.00 mg/l Cl₂ Spectroquant® 1200 tests / Fibre case Merck 100602 Chlorine Test (total chlorine) Method: photometric, DPD 0.010 - 6.00 mg/l Cl₂ Spectroquant® 1200 tests / Fibre case LB.M.1006020002
Merck 100602 Chlorine Test (total chlorine) Method: photometric, DPD 0.010 - 6.00 mg/l Cl₂ Spectroquant® 1200 tests / Fibre case

Tavsiye Et

*
*
*
IdeaSoft® | E-Ticaret paketleri ile hazırlanmıştır.