Merck 101804 Chloride Cell Test Method: photometric 0.5 - 15.0 mg/l Cl⁻ Spectroquant® 25 Test/EPS Kutu
Sınırlı Stok

Merck 101804 Chloride Cell Test Method: photometric 0.5 - 15.0 mg/l Cl⁻ Spectroquant® 25 Test/EPS Kutu

Marka
Stok Kodu
LB.M.1018040001
Merck 101804 Chloride Cell Test Method: photometric 0.5 - 15.0 mg/l Cl⁻ Spectroquant® 25 Test/EPS Kutu
Catalogue Number 101804
Overview This Spectroquant® Chloride test allows the accurate quantification of chloride ions in various waters and waste water. Their concentration depends on geological factors and the general local situation.

Within the test chloride ions react with mercury(II)-thiocyanate to mercury(II) chloride. The liberated thiocyanide reacts with iron ions to form a read complex. The method is analogous to EPA 325.1 and APHA 4500-Cl- E.

All our Cell and Reagent Test Kits are equipped with the unique Live ID which allows seamless method recognition and contains essential information such as lot number, expiry date, and automatic calibration updates.

The Spectroquant® Cell Tests come with prefilled 16 mm round cells as well as all the required reagents to perform the analysis according to the procedure described in the accompanying instruction leaflet.
Merck 101804 Chloride Cell Test Method: photometric 0.5 - 15.0 mg/l Cl⁻ Spectroquant® 25 Test/EPS Kutu 
Product Information
HS Code 3822 19 00
Quality Level MQ100
Safety Information according to GHS
Hazard Pictogram(s) Hazard Pictogram(s)
Hazard Pictogram(s)
Hazard Pictogram(s)
Hazard Pictogram(s)
Hazard Statement(s) H290: May be corrosive to metals.
H302 + H332: Harmful if swallowed or if inhaled.
H311: Toxic in contact with skin.
H314: Causes severe skin burns and eye damage.
H373: May cause damage to organs through prolonged or repeated exposure.
H410: Very toxic to aquatic life with long lasting effects.
EUH071: Corrosive to the respiratory tract.
Precautionary Statement(s) P273: Avoid release to the environment.
P280: Wear protective gloves/ protective clothing/ eye protection/ face protection/ hearing protection.
P303 + P361 + P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water.
P304 + P340 + P310: IF INHALED: Remove person to fresh air and keep comfortable for breathing. Immediately call a POISON CENTER/doctor.
P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P314: Get medical advice/ attention if you feel unwell.
Signal Word Danger
Storage class 6.1C Combustible, acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
WGK WGK 3 highly hazardous to water
Storage and Shipping Information
Storage Store at +15 °C to +25 °C.
Transport Information
Declaration (railroad and road) ADR, RID UN 3316 Chemie-Testsatz, 9, II
Declaration (transport by air) IATA-DGR UN 3316 CHEMICAL KIT, 9, II
Declaration (transport by sea) IMDG-Code UN 3316 CHEMICAL KIT, 9, II
 
Bu ürünün fiyat bilgisi, resim, ürün açıklamalarında ve diğer konularda yetersiz gördüğünüz noktaları öneri formunu kullanarak tarafımıza iletebilirsiniz.
Görüş ve önerileriniz için teşekkür ederiz.
Merck 101804 Chloride Cell Test Method: photometric 0.5 - 15.0 mg/l Cl⁻ Spectroquant® 25 Test/EPS Kutu Merck 101804 Chloride Cell Test Method: photometric 0.5 - 15.0 mg/l Cl⁻ Spectroquant® 25 Test/EPS Kutu LB.M.1018040001
Merck 101804 Chloride Cell Test Method: photometric 0.5 - 15.0 mg/l Cl⁻ Spectroquant® 25 Test/EPS Kutu

Tavsiye Et

*
*
*
 
DLAB ürünlerinde özel fısatlar
IdeaSoft® | E-Ticaret paketleri ile hazırlanmıştır.