Merck 114552 Chromate Cell Test (chromium VI and total chromium) 25 tests / EPS box
Catalogue Number 114552
Overview The method is analogous to APHA 3500-Cr B and DIN 38405-24.
USEPA approved for wastewater.

This Spectroquant® Chromate Cell Test allows the accurate quantification of the chromium(VI) and total chromium concentration in aqueous samples.

Method applied: In weakly phosphoric solution chromium(VI) ions react with diphenylcarbazide to form chromium(III) and diphenylcarbazone which form a red-violet complex that is determined photometrically.

The Spectroquant® Cell Tests come with prefilled 16 mm round cells and all the required reagents to perform the analysis according to the instruction leaflet provided.

All Spectroquant®Cell and Reagent Tests are equipped with the unique Live ID which allows seamless method recognition and contains essential information such as lot number, expiry date, and automatic calibration updates.
Merck 114552 Chromate Cell Test (chromium VI and total chromium) Method: photometric 0.05 - 2.00 mg/l Cr 0.11 - 4.46 mg/l CrO₄ Spectroquant® 25 tests / EPS box 
Product Information
HS Code 3822 19 00
Quality Level MQ100
Safety Information according to GHS
Hazard Pictogram(s) Hazard Pictogram(s)
Hazard Pictogram(s)
Hazard Pictogram(s)
Hazard Pictogram(s)
Hazard Statement(s) H272: May intensify fire; oxidizer.
H290: May be corrosive to metals.
H314: Causes severe skin burns and eye damage.
H317: May cause an allergic skin reaction.
H334: May cause allergy or asthma symptoms or breathing difficulties if inhaled.
H335: May cause respiratory irritation.
Precautionary Statement(s) P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P220: Keep away from clothing and other combustible materials.
P280: Wear protective gloves/ protective clothing/ eye protection/ face protection/ hearing protection.
P303 + P361 + P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water.
P304 + P340 + P310: IF INHALED: Remove person to fresh air and keep comfortable for breathing. Immediately call a POISON CENTER/doctor.
P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Signal Word Danger
Storage class 5.1B Oxidizing hazardous materials
WGK WGK 3 highly hazardous to water
Storage and Shipping Information
Storage Store at +15 °C to +25 °C.
Transport Information
Declaration (railroad and road) ADR, RID UN 3316 Chemie-Testsatz, 9, II
Declaration (transport by air) IATA-DGR UN 3316 CHEMICAL KIT, 9, II
Declaration (transport by sea) IMDG-Code UN 3316 CHEMICAL KIT, 9, II
Bu ürünün fiyat bilgisi, resim, ürün açıklamalarında ve diğer konularda yetersiz gördüğünüz noktaları öneri formunu kullanarak tarafımıza iletebilirsiniz.
Görüş ve önerileriniz için teşekkür ederiz.
Merck 114552 Chromate Cell Test (chromium VI and total chromium) Method: photometric 0.05 - 2.00 mg/l Cr 0.11 - 4.46 mg/l CrO₄ Spectroquant® 25 tests / EPS box Merck 114552 Chromate Cell Test (chromium VI and total chromium) Method: photometric 0.05 - 2.00 mg/l Cr 0.11 - 4.46 mg/l CrO₄ Spectroquant® 25 tests / EPS box LB.M.1145520001
Merck 114552 Chromate Cell Test (chromium VI and total chromium) Method: photometric 0.05 - 2.00 mg/l Cr 0.11 - 4.46 mg/l CrO₄ Spectroquant® 25 tests / EPS box

Tavsiye Et

*
*
*
IdeaSoft® | E-Ticaret paketleri ile hazırlanmıştır.