Merck 114730 Chloride Cell Test Method: photometric 5 - 125 mg/l Cl⁻ Spectroquant® 25 units / EPS box

Marka
Stok Kodu
LB.M.1147300001
4.698,68 TL + KDV
5.638,41 TL
Merck 114730 Chloride Cell Test Method: photometric 5 - 125 mg/l Cl⁻ Spectroquant® 25 units / EPS box
Catalogue Number 114730
Overview This Spectroquant® Chloride test allows the accurate quantification of chloride ions in various waters and waste water. Their concentration depends on geological factors and the general local situation.

Within the test chloride ions react with mercury(II)-thiocyanate to mercury(II) chloride. The liberated thiocyanide reacts with iron ions to form a read complex. The method is analogous to EPA 325.1 and APHA 4500-Cl- E.

All our Cell and Reagent Test Kits are equipped with the unique Live ID which allows seamless method recognition and contains essential information such as lot number, expiry date, and automatic calibration updates.

The Spectroquant® Cell Tests come with prefilled 16 mm round cells as well as all the required reagents to perform the analysis according to the procedure described in the accompanying instruction leaflet.
Merck 114730 Chloride Cell Test Method: photometric 5 - 125 mg/l Cl⁻ Spectroquant® 25 units / EPS box 
Product Information
HS Code 3822 19 00
Quality Level MQ100
Safety Information according to GHS
Hazard Pictogram(s) Hazard Pictogram(s)
Hazard Pictogram(s)
Hazard Pictogram(s)
Hazard Pictogram(s)
Hazard Statement(s) H290: May be corrosive to metals.
H302: Harmful if swallowed.
H311: Toxic in contact with skin.
H314: Causes severe skin burns and eye damage.
H373: May cause damage to organs through prolonged or repeated exposure.
H410: Very toxic to aquatic life with long lasting effects.
Precautionary Statement(s) P273: Avoid release to the environment.
P280: Wear protective gloves/ protective clothing/ eye protection/ face protection/ hearing protection.
P301 + P312: IF SWALLOWED: Call a POISON CENTER/doctor if you feel unwell.
P303 + P361 + P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water.
P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P314: Get medical advice/ attention if you feel unwell.
Signal Word Danger
Storage class 6.1C Combustible, acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
WGK WGK 3 highly hazardous to water
Storage and Shipping Information
Storage Store at +15 °C to +25 °C.
Transport Information
Declaration (railroad and road) ADR, RID UN 3316 Chemie-Testsatz, 9, II
Declaration (transport by air) IATA-DGR UN 3316 CHEMICAL KIT, 9, II
Declaration (transport by sea) IMDG-Code UN 3316 CHEMICAL KIT, 9, II
Bu ürünün fiyat bilgisi, resim, ürün açıklamalarında ve diğer konularda yetersiz gördüğünüz noktaları öneri formunu kullanarak tarafımıza iletebilirsiniz.
Görüş ve önerileriniz için teşekkür ederiz.
Merck 114730 Chloride Cell Test Method: photometric 5 - 125 mg/l Cl⁻ Spectroquant® 25 units / EPS box Merck 114730 Chloride Cell Test Method: photometric 5 - 125 mg/l Cl⁻ Spectroquant® 25 units / EPS box LB.M.1147300001
Merck 114730 Chloride Cell Test Method: photometric 5 - 125 mg/l Cl⁻ Spectroquant® 25 units / EPS box

Tavsiye Et

*
*
*
 
DLAB ürünlerinde özel fısatlar
IdeaSoft® | E-Ticaret paketleri ile hazırlanmıştır.