Hoşgeldiniz
Hızlı ve Güvenli Alışverişe Giriş Yapın!
Üye Değil misiniz?
Kolayca Üye Olabilirsiniz.

Merck 114785 Nitrite Test Method: photometric 0.002 - 1.00 mg/l NO₂-N 0.007 - 3.28 mg/l NO₂⁻ Spectroquant® 335 tests / Fibre case

Marka
Stok Kodu
LB.M.1147850001
Stoktan Teslim
Merck 114776 Nitrite Test Method: photometric 0.002 - 1.00 mg/l NO₂-N 0.007 - 3.28 mg/l NO₂⁻ 
Catalogue Number 114776
Overview The method is analogous to EPA 354.1, APHA 4500-NO2- B, and DIN EN 26 777.

This Spectroquant® Nitrate Cell Test allows the accurate quantification of nitrate in water samples. Nitrate is an essential nutrient required for the growth of animals and plants. However, elevated levels of nitrate can be a health risk, in particular for pregnant women and infants. Therefore, nitrate levels in water sources are regulated in many countries.

Method applied: In acidic solution nitrite ions react with sulfanilic acid to form a diazonium salt that reacts with N-(1-naphthyl)ethylenediamine dihydrochloride to form a red-violet azo dye which is determined photometrically.

The Spectroquant® Reagent Test Kits contain highly stable, ready-to-use reagent mixtures to perform the analysis according to the procedure described in the accompanying instruction leaflet.

All our Cell and Reagent Test Kits are equipped with the unique Live ID which allows seamless method recognition and contains essential information such as lot number, expiry date, and automatic calibration updates.
Merck 114776 Nitrite Test Method: photometric 0.002 - 1.00 mg/l NO₂-N 0.007 - 3.28 mg/l NO₂⁻ Spectroquant® 1000 tests / Fibre case 
Product Information
HS Code 3822 19 00
Quality Level MQ100
Safety Information according to GHS
Hazard Pictogram(s) Hazard Pictogram(s)
Hazard Statement(s) H315: Causes skin irritation.
H317: May cause an allergic skin reaction.
H319: Causes serious eye irritation.
Precautionary Statement(s) P261: Avoid breathing dust.
P264: Wash skin thoroughly after handling.
P272: Contaminated work clothing should not be allowed out of the workplace.
P280: Wear protective gloves/ eye protection/ face protection.
P302 + P352: IF ON SKIN: Wash with plenty of water.
P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Signal Word Warning
Storage class 10 - 13 Other liquids and solids
WGK WGK 2 obviously hazardous to water
Storage and Shipping Information
Storage Store at +15 °C to +25 °C.
Bu ürünün fiyat bilgisi, resim, ürün açıklamalarında ve diğer konularda yetersiz gördüğünüz noktaları öneri formunu kullanarak tarafımıza iletebilirsiniz.
Görüş ve önerileriniz için teşekkür ederiz.
Merck 114785 Nitrite Test Method: photometric 0.002 - 1.00 mg/l NO₂-N 0.007 - 3.28 mg/l NO₂⁻ Spectroquant® 335 tests / Fibre case Merck 114776 Nitrite Test Method: photometric 0.002 - 1.00 mg/l NO₂-N 0.007 - 3.28 mg/l NO₂⁻ Spectroquant® 335 tests / Fibre case LB.M.1147850001
Merck 114785 Nitrite Test Method: photometric 0.002 - 1.00 mg/l NO₂-N 0.007 - 3.28 mg/l NO₂⁻ Spectroquant® 335 tests / Fibre case

Tavsiye Et

*
*
*
 
DLAB ürünlerinde özel fısatlar
IdeaSoft® | E-Ticaret paketleri ile hazırlanmıştır.