Hoşgeldiniz
Hızlı ve Güvenli Alışverişe Giriş Yapın!
Üye Değil misiniz?
Kolayca Üye Olabilirsiniz.

Merck 114554 Nickel Cell Test Method: photometric 0.10 - 6.00 mg/l Ni Spectroquant® 25 tests / Fibre case

Marka
Stok Kodu
LB.M.1145540001
5.596,54 TL + KDV
6.715,85 TL
Stoktan Teslim
Merck 114554 Nickel Cell Test Method: photometric 0.10 - 6.00 mg/l Ni Spectroquant® 
Catalogue Number 114554
Overview This Spectroquant® Nickel test allows the accurate quantification of nickel ions in various waters. Nickel(II) ions are oxidized by iodine and then transformed with dimethylglyoxime in an ammoniacal solution into a red-brown complex that is determined photometrically.

MQuant® test strips can be used for pre-testing a sample in an economic and quick way to estimate the nickel concentration and a possible dilution factor prior to using a quantitative method such as the Spectroquant® test.

All our Cell and Reagent Test Kits are equipped with the unique Live ID which allows seamless method recognition and contains essential information such as lot number, expiry date, and automatic calibration updates.

The Spectroquant® Cell Tests come with prefilled 16 mm round cells as well as all the required reagents to perform the analysis according to the procedure described in the accompanying instruction leaflet.
Merck 114554 Nickel Cell Test Method: photometric 0.10 - 6.00 mg/l Ni Spectroquant® 25 tests / Fibre case 
Product Information
HS Code 3822 19 00
Quality Level MQ100
Safety Information according to GHS
Hazard Pictogram(s) Hazard Pictogram(s)
Hazard Pictogram(s)
Hazard Pictogram(s)
Hazard Pictogram(s)
Hazard Statement(s) H225: Highly flammable liquid and vapour.
H314: Causes severe skin burns and eye damage.
H335: May cause respiratory irritation.
H410: Very toxic to aquatic life with long lasting effects.
Precautionary Statement(s) P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P233: Keep container tightly closed.
P273: Avoid release to the environment.
P280: Wear protective gloves/ protective clothing/ eye protection/ face protection/ hearing protection.
P303 + P361 + P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water.
P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Signal Word Danger
Storage class 3 Flammable liquids
WGK WGK 2 obviously hazardous to water
Storage and Shipping Information
Storage Store at +15 °C to +25 °C.
Transport Information
Declaration (railroad and road) ADR, RID UN 3316 Chemie-Testsatz, 9, II
Declaration (transport by air) IATA-DGR UN 3316 CHEMICAL KIT, 9, II
Declaration (transport by sea) IMDG-Code UN 3316 CHEMICAL KIT, 9, II
Bu ürünün fiyat bilgisi, resim, ürün açıklamalarında ve diğer konularda yetersiz gördüğünüz noktaları öneri formunu kullanarak tarafımıza iletebilirsiniz.
Görüş ve önerileriniz için teşekkür ederiz.
Merck 114554 Nickel Cell Test Method: photometric 0.10 - 6.00 mg/l Ni Spectroquant® 25 tests / Fibre case Merck 114554 Nickel Cell Test Method: photometric 0.10 - 6.00 mg/l Ni Spectroquant® 25 tests / Fibre case LB.M.1145540001
Merck 114554 Nickel Cell Test Method: photometric 0.10 - 6.00 mg/l Ni Spectroquant® 25 tests / Fibre case

Tavsiye Et

*
*
*
 
DLAB ürünlerinde özel fısatlar
IdeaSoft® | E-Ticaret paketleri ile hazırlanmıştır.